<Error>
<ErrorNumber>38141</ErrorNumber>
<ErrorFamily>Main Plot Control</ErrorFamily>
<ErrorMessage>
MPC: The proof carrier is not positioned correctly or is not the correct size
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The proofing carrier was loaded incorrectly, so that it is not at the
expected position on the drum.  Each carrier has a hole at the leading edge.
The firmware searches for this hole if optical verification is enabled.  If
the carrier is correctly positioned on the drum, the firmware will find this
hole, indicating that the carrier is of the correct type (each type of carrier
has a different hole position) and is loaded properly to line up the vacuum
holes with the drum.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><UnnumberedList>
<ListItem><Text>
Reload carrier.
</Text></ListItem>
<ListItem><Text>
Check carrier type to make sure it is correct.
</Text></ListItem>
</UnnumberedList></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Carrier not positioned correctly before pressing the load button.
</Cause>
<Cause>
Carrier is not the type that is supposed to have been loaded.
</Cause>
<LastModified>
02-Sep-2003
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:10 2008 PST
</Updated>
<Links>
</Links>
</Error>